REMOVAL OF HOUSING
3
SWITCHES
Program selector:
2
- position switch
= AUTOMATIC: The impulse device connected to the door
operator will open the door and close it after a preset door open
time. The hold open time can be adjusted between 0...60 s
(control points 7 or 17).
Power-assisted manual opening is also active during this period.
= The door opens and remains open. On switching to either
AUTO or MANUAL the door will close after a preset delay.
AUTO
OPEN
IO
AUTO
OPEN
Warning!
Disconnect mains supply
when removing or
mounting the housing.
Remove the housing by
inserting a wide-blade
screw driver at each
end.
The automatic swing door operator is mounted
with the end to the is
located towards the hinge side of the door. When the
door operator is switched on, the red LED on the
mains switch lights up. The mains supply
should always be on to ensure that the back-up
battery is being charged.
mains switch
Switch:I=ON,0=OFF.
Disconnect mains
supply when
making electrical
connections.