11
Assembly of the operator and the standard arm to the closing side
Hinge line
Mounting of the operator
M8x22 and washer
70
45
Min. 40
297
Y
90°
After installation, ensure that the arm and door are properly adjusted.
• Mount a door stop to the door open position so that wind will not
drive the door against the wall, resulting in damage.
Tighten the holding screw.
Mounting of the arm to the operator M8x30 and washer
Y (mm) Length of extension piece
0 No extension piece
10 10 mm (DA150/01)
20 20 mm (DA150/02)
30 30 mm (DA150/01, DA150/02)
40 40 mm (DA150/02 * 2 kpl)
60 60 mm (DA150/06)
Frame depth
Frame depth
DA147 0-150mm
DA148 150-250mm

Related product manuals