12
Assembly of the operator and the sliding arm DA149 to the closing side
• After installation, ensure that the arm and door are properly adjusted.
• Mount a door stop to the door open position so that wind will not
drive the door against the wall, resulting in damage.
• Tighten the holding screw.
Y
297
Min. 37*
M
L
585
Mounting of the operator
M8x22 and washer
Hinge line
* From the mounting plate to the
mounting hole of the sliding rail,
without extension piece.
Y (mm) Length of extension piece
47 10 mm (DA150/01)
57 20 mm (DA150/02)
67 30 mm (DA150/01, DA150/02)
77 40 mm (DA150/02 2 pcs)
97 60 mm (DA150/06)
Mounting of the arm to the operator M8x30 and washer.
It is always recommended to use 10 mm extension piece.
Frame depth
DA149
Frame
depth
H/mm
Arm
distance
L/mm
Minimum
door width
M/mm
0-24
25-75
75-100
130
120
115
750
740
735