206 CHAPTER 20
Appendix
Polyphonic Pressure
message (only Page B)
Ac Status byte, c=MIDI channel
nn Parameter Number 0..127
(see parameter list Page B)
vv :Parameter Value 0..127
see parameter list Page B)
Example: A2,07,25 Control LFO3 Rate on
MIDI channel 3 (!).
System-Exclusive-Mes-
sage
F0 Start of System Exclusive
00 Manufacturer ID 1
Access Music Electronics
20 Manufacturer ID 2
Access Music Electronics
33 Manufacturer ID 3
Access Music Electronics
01 Product ID (Virus)
dd Device ID
00..0F individual; 10: omni.
... [message]
F7 End of System Exclusive
SysEx Parameterchange
[message]=
7x Parameterchange
70:page A;
71:page B;
72:page
C pp Part number
00..0F Multi part 1..16;
40: Single
nn Parameter Number
0..127 (see parameter list)
vv Parameter Value0..127
(see parameter list)
{F0,00,20,33,01,dd,7x,pp,nn,vv,F7}
. The SysEx Parameterchange affects
one of the sixteen single edit buffer in
Multi Mode addressed by the part num-
ber (00..0F) or the Single buffer in Single
Mode (part number 40). If a global
parameter or a Multi parameter is
accessed, which is not part-sensitive (e.g.
Input Boost or Multi Delay Time), the
part number is ignored.
Example:
F0,00,20,33,01,10,70,05,28,5F,F7
Set Cutoff on Part 6 to decimal
value 95. (10: device ID omni; 70: page A,
05: part 6; 28: parameter Cutoff, 5F: deci-
mal value 95)

Table of Contents