33
NOTE: Never install the Second Stage filter in the front filter channel. The Second Stage filter
must be installed behind a UL Classified Grease-X-Tractor™ primary filter Model HE or XX.
1. Slide the top edge of the Second Stage filter into the top rear filter channel; Fig. 53.
2. Lifting the lower edge of the filter past the grease trough, continue to push the top of the filter into
the channel.
3. When the filter is even with the bottom rear filter channel, set the filter into the channel; Fig. 54.
4. Slide the filter to one end of the hood and repeat until all the filters are installed. Make sure the
filters are placed tightly together with no visible gaps.
5. Latch filters together by connecting hooks to handle on next filter; Fig. 55.
6. Install the Grease-X-Tractor™ primary filters in the same manner using the front filter channel.
Fig. 55Fig. 54Fig. 53
Grease Grabber™ Filter Installation