EasyManua.ls Logo

Acer PD100 - Page 57

Acer PD100
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51 Chapter 4
No Step Specification Procedure
7 Light Leak The unit can't
accept the
leakage is
brighter than
Gray 10 pattern
- Test Signal : 800x600@75Hz (PD100)
- Test Pattern : 32 Grays, Gray 10_HP, Gray 30_HP
(From Top to Bottom)
- Please check and see if the light leaks.
- Follow up TI DMD Chip Spec.
8 Calibration Calibration
Pattern should
be in full screen
mode
- Once Main Board is changed, firmware upgrade,
Video Calibration & ADC Calibration should be
done as well.
- Video Calibration
- Test Signal : 720x480@75Hz (PD100)
- Test Pattern : Master
- PC Calibration
- Test Signal : 800x600@75Hz (PD100)
- Test Pattern : White (Top) Black (Bottom)
Note:
1. Calibration Pattern should be in Full Screen
Mode.
2. Please refer to 4-6. Guide to Entering Service
Mode and Facotry Reset for entering Service
Mode.
3. Choose and access Video Calibration & PC
Calibration for correction in Service Mode.
Choose "Exit" to leave the Service Mode after all.
9 Contrast /
Brightness
Gray level should
be
distinguishable
and without color
abnormal
- Test Pattern: 64 RGBW scale
10 R, G, B and
White Color
Performance
Each R, G, B
color should be
normal without
color abnormal
issue
- Test Pattern: R, G, B and White Color

Other manuals for Acer PD100

Related product manuals