CTpro 3000 Operating Instructions Firmware Version 1.24
14
*First it is required to select a door.
Exit from menu is automatic if no keys
are pressed for a period of time.
Door Settings* Timers Relay Time Time for which relay is active
(contd.) Extended Time period when relay is active for an
Relay Time extended time
OP2 Time Time for which OP2 is active
OP3 Time Time for which OP3 is active
Ajar Time Max time which door can be open
AUX Time Time for which AUX output is active
Reporting Door Ajar Buzzer o/p active if door left ajar
Door Forced Door Forced events report in log
Door Open Door Open events report in log
Door Closed Door Closed events report in log
Push Button Push Button events report in log
Read Error Log and report reader errors
Mains Fault Log and Report an electric Mains Fault
Timed Actions Unlock Door Specify times when door is unlocked
Lock Door Specify times when door is locked
PIN Required Specify times when PIN is required
Any Card Specify times when any
card gains access
Activate OP2 Specify times when OP2 is active
Activate OP3 Specify times when OP3 is active
Activate AUX Specify times when AUX is active
PIN Only Specify times for PIN Only operation
PIN or Card Specify times for PIN or Card operation
Twin Users Two different cards required for access
Normalise Specify times when door is normalised
Assign Name Assign a name to a door
Communications Set Address Set the network address of this door
Direct Conn. Specifies that this controller is connected directly to a PC
Comms Speed Select communications speed
Slave Mode Specifies that this controller is a slave under ACT5000pc
No Hist. Log Disables the reporting of offline log events in slave mode.
Print All Enables real-time logging on attached serial printer
Remote Doors Enable/Disable remote doors connected via ACTpro 100 modules
IO Modules Enable/Disable Input/Output modules
Set Password Set a password for remote communications
TCP/IP Settings IP Address Sets the IP address of the Controller
TCP Port Num Sets the TCP port number for comms. with ACTWinPro.
Network Mask Sets the Network Mask.
Default Gateway
Set the default gateway (also known as default route).
MAC Address Displays the MAC address.
Central/Sat Central Server Enable/Disable ACTpro 3000 as Central Server
Central IP Addr Set the IP address of the Central Server
Card Setup Site Code 1 Enter the primary site code for the system
Site Code 2 Enter a secondary site code for the system
Card Format Enter a custom card format for the system
Diagnostics Version Displays the current software version
Reader test Reads a card and displays the received information.
Last Reset Displays a code indicating the reason for the last reset.
Factory Diag. For Factory Use only. Do not use.
Change PIN Change the PIN used to access the Installer menu
Factory Defaults Restore the system to its factory default settings.