ACTpro 3000 Operating Instructions Firmware Version 1.24
13
Installer Menu
*Installer will first be required to select a door.
System Settings Operation PIN Only PINs alone are used to gain access.
Learn All 30000 may use random coded cards.
Exit PINs Exit PINs may be used in PIN only mode.
User Limiting Prevent access if the user limit is reached.
One-To-One Card numbers may be assigned to all users.
Multiple Users may have multiple cards.
Display Backlight Keypad backlight enabled
Keypad Beep Keypad beep enabled
Show Status Display current status of doors on LCD
Show Events Display events on LCD as they occur
Handshake Use handshake line when printing
Tech Bleep Controller bleeps for technical fault
Language Set the controllers operational Language.
PIN Length Sets the length of user/group PIN codes.
Fire Doors Allows the definition of doors with fire override.
User Tracking Perimeter Define Perimeter doors
Antipassback Define Antipassback doors
Timed Define Timed Antipassback doors
antipassback
Internal Doors Define Internal doors
Tracking Reset Set time for auto-reset (auto-logout)
User Limits Set user limits A & B
Outputs Door 1 Define door 1 output special functions
Door 2 Define door 2 output special functions
Door Settings* Operation Push Button Door release button enabled
Lock Saver Relay de-energized as door opens
Chime Buzzer sounds as door opens
Guest Button
on external keypad fires AUX/buzzer
Exit Always Timezones don’t apply to exit readers
Interlock Only one door may be open at any time.
Silent Confirmation tones disabled
Exit PIR Door stays open while Push Button closed
Failsafe Door relay is normally energised
Toggle Relay Door has toggle operation
Monitor Arm AUX input monitors Intruder panel status
Alarms Door Forced Aux relay activated if door forced
Door Ajar Aux relay activated if door left ajar
Duress Alarm Aux relay activated by duress code
Door Open Aux relay active while door open
Acc. Granted Aux relay fires access granted
Exit Granted Aux relay fires Exit denied
Acc. Denied Aux relay fires when access denied.
Exit Denied Aux relay fires when Exit denied.
Relay Follow Aux relay active if main Relay is active.
Arm Intruder Aux relay activates to arm Intruder panel