TROUBLESHOOTING
Problem Possible Solution
Bad
Wireless Sensor
Reception
T11IIno bars
Relocate the main unit and/or the wireless
sensor. Both units must be within 330 feet
(100m) from each other. Make sure both
units are placed at least 3 feet (.91 m) from
other electronic appliances and devices that
may interfere with the wireless
communication (such as TV's, microwaves,
computers etc). NOTE: It may take up to 20
minutes for the main unit to re-synchronize
with the sensor when batteries are replaced.
Use lithium batteries in sensor when
temperature is below -4°F (-20°C).
No Wireless Sensor Data
(no communication)
'I,
no bars and flashing
- T1
JI - JI data
, I
If wireless reception is bad (no bars), see
"Bad Reception" section above. The wireless
ID setting on each unit must match for all
units to communicate properly. See "Set
Wireless ID" on the next page.
Display Console
Screen Not Working
Make certain that the batteries are installed
correctly.
Batteries may need replacing
Please DO NOT return product to the retail store.
For technical assistance and product return information, please call
Customer Care:
877-221-1252 Mon. - Fri. 8:00 A.M. to 4:30 P.M. ICST]
www.chaneyinstrument.com
PRODUCTREGISTUTION
To receive product updates
and information,
Log on to
www.chaneyinstrument.com
5
TROUBLESHOOTING
Set Wireless ID
This wireless thermometer
uses long range 433mhz
radio frequency for
communication.
In the event that you have
reception problems due to
interference, both the
display unit and the
wireless sensor have
a selectable wireless ID.
The ID switches are
located within the battery
compartments of the
display unit and the
wireless sensor.
You may choose
A, B or C;
but both the display unit
and the
wireless sensor
ID's must match
for
successful synchronization.
SPECIFICATIONS
Product Facts
Batteries: 5 x "AP:' (not included)
Lithium Batteries Recommended in
Outdoor Sensor if temperatures are
below-4°F
Measurement Ranges
Outdoor Temperature: -40°F to 158°F
-40°Cto 70°C
Outdoor Humidity:
1%to99% RH
Indoor Temperature:
Indoor Humidity:
16%to98% RH
Wireless Range: 330 ft/ 1oom MAX
Depending on home construction materials
Both wireless ID's
must match
MADE IN CHINA
HECHO EN CHINA
Limited One
Year Warranty
Instructions&
Warranty Enclosed
Customer Care:
877-221-1252
www.chaneyinstrument.com