Do you have a question about the Adaptec 3405 and is the answer not in the manual?
Form Factor | Low profile |
---|---|
Data Transfer Rate | 6 Gbps |
Supported RAID Levels | 0, 1, 5, 10, 50 |
Cache Memory | 512 MB |
Controller Type | SAS |
Interface | PCIe 2.0 x8 |
Explains the TSID number and its importance for technical support.
Provides contact information and web resources for technical support in North America.
Lists contact details and web links for Adaptec technical support in Europe.
Provides contact number for Adaptec technical support in Japan.
Provides contact number for Adaptec technical support in Australia.
Details FCC regulations and measures to avoid radio frequency interference.
Lists compliance with EMC Directive and various EN standards for IT equipment.
States compliance with Australian/New Zealand standards for digital devices.
Confirms compliance with Canadian Interference-Causing Equipment Regulations.
Describes compliance with Japanese VCCI standards for IT equipment.
Outlines prerequisites and background knowledge for using the guide.
Defines key terms used throughout the Adaptec RAID controller guide.
Lists other documents and resources for obtaining further information.
Lists the items included in the Adaptec RAID controller kit.
Specifies the hardware and software prerequisites for installing and using the controller.
Details the common features supported by Adaptec RAID controllers.
Describes features related to RAID array creation and management.
Highlights advanced features for data protection on 5-Series and 3-Series controllers.
Explains how to add a battery backup module and lists supported models.
Details the features, form factor, and specifications of the Adaptec RAID 5085 controller.
Details the features, form factor, and specifications of the Adaptec RAID 5405 controller.
Details the features, form factor, and specifications of the Adaptec RAID 5445 controller.
Details the features, form factor, and specifications of the Adaptec RAID 5805/5805Q controllers.
Details the features, form factor, and specifications of the Adaptec RAID 51245 controller.
Details the features, form factor, and specifications of the Adaptec RAID 51645 controller.
Details the features, form factor, and specifications of the Adaptec RAID 52445 controller.
Details the features, form factor, and specifications of the Adaptec RAID 5405Z controller.
Details the features, form factor, and specifications of the Adaptec RAID 5445Z controller.
Details the features, form factor, and specifications of the Adaptec RAID 5805Z/5805ZQ controllers.
Details the features, form factor, and specifications of the Adaptec RAID 3085 controller.
Details the features, form factor, and specifications of the Adaptec RAID 3405 controller.
Details the features, form factor, and specifications of the Adaptec RAID 3805 controller.
Details the features, form factor, and specifications of the Adaptec RAID 31205 controller.
Details the features, form factor, and specifications of the Adaptec RAID 31605 controller.
Details the features, form factor, and specifications of the Adaptec RAID 2045 controller.
Details the features, form factor, and specifications of the Adaptec RAID 2405/2405Q controllers.
Details the features, form factor, and specifications of the Adaptec RAID 2805 controller.
Provides an overview of supported RAID levels and drive requirements.
Guides on selecting compatible disk drives and the necessary cables.
Outlines the two primary installation methods for the controller.
Describes the fundamental steps involved in installing the controller.
Lists essential checks and preparations before controller installation.
Provides step-by-step instructions for physically installing the RAID controller.
Guides on connecting internal and external disk drives to the controller.
Explains how to connect external storage devices to the controller.
Directs users to subsequent tasks after installation.
Explains how to configure the system BIOS to boot from the RAID controller.
Details the process of creating a RAID array using the available utilities.
Guides on making the created array the bootable device.
Outlines initial steps and considerations before driver installation.
Explains how to create a bootable driver disk for OS installation.
Provides instructions for installing drivers during Windows OS setup.
Guides on installing drivers during Red Hat Linux OS setup.
Guides on installing drivers during SUSE Linux OS setup.
Guides on installing drivers during OpenServer OS setup.
Guides on installing drivers during UnixWare OS setup.
Guides on installing drivers during Solaris OS setup.
Guides on installing drivers during VMware OS setup.
Guides on installing drivers during FreeBSD OS setup.
Outlines steps before installing drivers on an existing OS.
Explains how to create a driver disk for installing on an existing OS.
Instructions for installing drivers on Windows OS.
Instructions for installing drivers on Red Hat or SUSE Linux.
Instructions for installing drivers on OpenServer.
Instructions for installing drivers on UnixWare.
Instructions for installing drivers on Solaris.
Instructions for installing drivers on VMware.
Instructions for installing drivers on FreeBSD.
Introduces Adaptec Storage Manager, a software application for storage management.
Describes ARCCONF, a command-line utility for array and configuration management.
Details the BIOS-based ARC utility and its tools for managing arrays.
Explains the Adaptec Flash Utility (AFU) for updating firmware.
Guides on selecting the appropriate utility for different management tasks.
Provides initial steps for diagnosing and resolving common controller issues.
Explains how to check the status of disk drives using LED indicators and software.
Describes methods to silence audible alarms triggered by controller errors.
Outlines procedures for recovering data after a disk drive failure.
Defines drive segments and their role in creating RAID arrays.
Explains RAID 0, its performance benefits, and lack of redundancy.
Describes RAID 1 mirroring for data redundancy and its capacity limitations.
Explains RAID 1E, a striped mirror array with increased drive support.
Details RAID 10, combining striping and mirroring for performance and redundancy.
Explains RAID 5, using striping and parity for redundancy and performance.
Describes RAID 5EE, featuring a distributed spare for faster rebuilds.
Explains RAID 50, combining multiple RAID 5 arrays for capacity and performance.
Details RAID 6, offering dual drive failure protection with two parity sets.
Explains RAID 60, combining multiple RAID 6 arrays for enhanced data protection.
Provides a guide to selecting RAID levels based on requirements.
Provides an overview of the Adaptec RAID Configuration utility and its tools.
Instructions on how to start the ARC utility.
Guides on using the Array Configuration Utility to create and manage RAID arrays.
Explains how to create and manage JBOD (Just a Bunch Of Disks) configurations.
Details managing the MaxIQ cache pool using SSDs for read-intensive operations.
Guides on using SerialSelect to modify controller and disk drive settings.
Explains how to format and verify disk drives using the utility.
Describes how to physically locate disk drives using the identify drive feature.
Explains how to view disk drive information and system displays.
Guides on accessing and viewing the controller's event log.
Explains how to create the ACU floppy disk and start the utility.
Guides on navigating the ACU interface using menus.
Details how to run the ACU using script files for automated configuration.
Lists the system requirements for running the Adaptec Flash Utility.
Outlines steps to prepare for firmware updates.
Instructions for using the menu-driven interface of the Adaptec Flash Utility.
Guides on executing the Adaptec Flash Utility from the DOS command line.
Provides detailed steps for updating controller firmware via the command line.
Details the LED and I2C connector pinout for the Adaptec RAID 5085.
Details the LED and I2C connector pinouts for Adaptec RAID 5405/5405Z.
Details the LED and I2C connector pinouts for the Adaptec RAID 51245.
Details the LED and I2C connector pinouts for the Adaptec RAID 51645.
Details the LED and I2C connector pinouts for the Adaptec RAID 52445.
Details the LED and I2C connector pinouts for the Adaptec RAID 31605.
Details the LED connector pinout for the Adaptec RAID 2045.
Details the LED and I2C connector pinouts for the Adaptec RAID 2805.
Lists environmental operating conditions for the RAID controllers.
Details the DC voltage and ripple requirements for the controllers.
Lists the typical current draw for various Adaptec RAID controller models.