L-852A-D, J & K ITCF, F-Range, ICAO LED Taxiway Centerline Light
96A0460 Rev. C
Troubleshooting
© ADB Airfield Solutions All Rights Reserved32
Water inside
optical chamber
Damaged or missing
prism seals or top
cover O-ring
Replace both prism seals. Replace top cover O-ring. Verify that
the fixture is sealed.
Fixture wires pinched
between base can
and fixture
A break in the fixture wire will cause water to be drawn into the
fixture during the fixture's heating and cooling cycle (when
switched on and off). Replace fixture leads.
Refer to “Replacing the Cord Set ” on page 24
Use care when remounting fixture on the base can to ensure that the
wires do not get pinched.
Problem Possible Cause Corrective Action