ENGLISH
6
8. INSTALLATION (ALL MODELS)
8.1.Water connection
If only cold water is available, connect as shown in figure 3. Where hot water is available, connect as shown in figure
4. If, in addition, decalcified water is available, connect as shown in figure 5
Required dynamic pressure: 2 ÷ 4 Kg/cm
2
.
VERY IMPORTANT: Bleed water circuit prior to installation and fitting filters.
8.2.Steam connection
If steam is available, the water will be heated by direct injection.
The connection diagram is shown in the figure.
Steam pressure: 2 ÷ 4 Kg/cm
2
.
VERY IMPORTANT: Bleed steam circuit prior to installation and fitting filters
After steam has been introduced into the machine for the first time, it is advisable for the steam hose nuts to be re-
tightened.
8.3.Drainage
Fix the drainage bend pipe as shown in the figure
A=Stopcock B=Filter C=Hose A.C.=Hot water A.F.=Cold water A.D.=Decalcified water
A= Drainage pipe bend
B=Clamp
Warning!
Failure to fit the filters on the water and steam
inputs will result in loss of cover under
guarantee for the corresponding components