EasyManua.ls Logo

ADC M-80p - Page 24

ADC M-80p
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24 American Dryer Corp. WFR113539-13
GAS SPECIFICATIONS FOR DRYERS GOING TO CE COUNTRIES**
Model
Gas
Type
Nominal
Heating Value
Supply
Pressure***
Gross
Heat Input
Fuel
Consumption
Orifice Siz e
Orifice
(Injector)
Quantity
Burner
Pressure
Btu/ft
3
mb Btu/hr kW DMS mm mb
AD-35i
Natural (I
2H
/I
2E
)1,000
15-30
70,000
20.50 1.981 M
3
/hr
22
3.988
1
9.0
Natural (I
2L
) 830
20-35
70,000
20.50 2.386 M
3
/hr
22
3.988
1
12.0
Natural (I
2ELL
) 830
15-30
70,000
20.50 2.386 M
3
/hr
22
3.988
1
12.0
*Natural (I
2E+
)
1,000
20
70,000
20.50 1.981 M
3
/hr
30
3.264
1
830
25
70,000
20.50 2.386 M
3
/hr
30
3.264
1
*Butane (I
3+
) 3,175
28-30
70,000
20.50 1.478 kg/hr
43
2.261
1
*Propane (I
3+
) 2,500
37
70,000
20.50 1.478 kg/hr
43
2.261
1
Butane (I
3B/P
) 3,175
28-30/50
70,000
20.50 1.478 kg/hr
41
2.438
1
20.0
Propane (I
3P
) 2,500
28-30/50
70,000
20.50 1.478 kg/hr
41
2.438
1
25.0
AD-50i
Natural (I
2H
/I
2E
)1,000
15-30
125,000
36.64 3.401 M3/hr
5
5.220
1
9.0
Natural (I
2L
) 830
20-35
125,000
36.64 4.098 M3/hr
5
5.220
1
12.0
Natural (I
2ELL
) 830
15-30
125,000
36.64 4.098 M3/hr
5
5.220
1
12.0
*Natural (I
2E+
)
1,000
20
125,000
36.64 3.401 M3/hr
17
4.394
1
-
830
25
125,000
36.64 4.098 M3/hr
17
4.394
1
-
*Butane (I
3+
) 3,175
28-30
125,000
36.64 2.537 kg/hr
32
2.946
1
-
*Propane (I
3+
) 2,500
37
125,000
36.64 2.537 kg/hr
32
2.946
1
-
Butane (I
3B/P
) 3,175
28-30/50
125,000
36.64 2.537 kg/hr
30
3.264
1
20.0
Propane (I
3P
) 2,500
28-30/50
125,000
36.64 2.537 kg/hr
30
3.264
1
25.0
AD-80i
Natural (I
2H
/I
2E
)1,000
15-30
135,000
39.53 3.826 M3/hr
2
5.613
1
9.0
Natural (I
2L
) 830
20-35
135,000
39.53 4.610 M3/hr
2
5.613
1
12.0
Natural (I
2ELL
) 830
15-30
135,000
39.53 4.610 M3/hr
2
5.613
1
12.0
*Natural (I
2E+
)
1,000
20
135,000
39.53 3.826 M3/hr
14
4.623
1
830
25
135,000
39.53 4.610 M3/hr
14
4.623
1
*Butane (I
3+
) 3,175
28-30
135,000
39.53 2.855 kg/hr
30
3.264
1
*Propane (I
3+
) 2,500
37
135,000
39.53 2.855 kg/hr
30
3.264
1
Butane (I
3B/P
) 3,175
28-30/50
135,000
39.53 2.855 kg/hr
29
3.454
1
20.0
Propane (I
3P
) 2,500
28-30/50
135,000
39.53 2.855 kg/hr
29
3.454
1
25.0
GAS SPECIFICATIONS FOR DRYERS GOING TO AUSTRALIA*
Model
Gas
Type
Supply
Pressure
Heat Input
Gross
Heat Input
Orifice Size
Orifice
(Injector)
Quantity
Burner
Pressure
kPa kW MJ/h DMS mm kPa
AD-35i
Natural
1.7-3.2 20.51 73.9
22
3.99
1
0.90
Propane
2.75 20.51 73.9
41
2.44
1
2.67
AD-50i
Natural
1.7-3.2 36.63 131.9
5
5.22
1
0.83
Propane
2.75 36.63 131.9
30
3.26
1
2.50
AD-80i
Natural
1.7-3.2 39.56 142.4
2
5.61
1
0.83
Propane
2.75 39.56 142.4
29
3.45
1
2.50
Shaded areas are stated in metric equivalents
* Gas valve’s internal regulator disabled.
** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
*** Nominal supply pressure.
Shaded areas are stated in metric equivalents
* Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
For Australia, refer to data plate.

Related product manuals