WFR113539 -13 www.adclaundry.com 35
Programming __________________________
Non-Coin Programming
Phase 7.2.2 OPL Diagnostic Codes
MAIN DOOR OPENED – A main door or door circuit is
open.
EXHAUST HIGH TEMP FAULT – Tumbler is above 180° F
(82.2° C).
LINT ACCESS OPEN – Lint drawer or lint door circuit is
open.
EXHAUST HIGH LIMIT FAULT – Temp. disk under tumbler
is open.
SAIL SWITCH CLOSED FAULT – Sail switch is closed –
should be open at the start of a cycle.
SAIL SWITCH OPEN FAULT – Sail switch remained open
after the cycle started. Should have closed.
BURNER HIGH LIMIT FAULT – Burner temp. disk has
opened.
BURNER IGNITION CONTROL – No signal to gas valve
from (DSI) module during trial for ignition time. DSI module
is bad.
IGNITION FAULT – Gas valve did not remain open after trial
for ignition. Indicates that no flame was detected.
FLAME FAULT – Flame was detected during trial for ignition
but failed later.
ROTATION FAULT – Indicates the tumbler is not rotating.
OPEN EXHAUST TEMPERATURE PROBE – Indicates the
exhaust temperature probe is open or shorted.
OPEN FIRE SUPPRESSION SYSTEM (F.S.S.) PROBE
FAULT – Indicates the temperature probe for the F.S.S. is
open or shorted.
LOW VOLTAGE FAULT – Volt dropped below the operating
value.
EE PROM FAULT ### – Error in memory location. Fault
correction: First cycle power to get the display to read
“ENTER PASSWORD”. Next press the keys FAA, then
press the ENTER key. Press the UP ARROW then “YES”
will be displayed. Now press the ENTER key and the
display should return to ready.
Inputs (Red L.E.D.)
All indications are with L.E.D. lit
ESTOP – Indicates E-STOP has been pressed.
GAS_V – Indicates the gas valve is open (ON).
BRHL – Indicates the burner high limit disk is closed.
SAIL – Indicates the sail switch is closed.
EXHL – Indicates the exhaust high limit disk is closed
(temperature below 190° F [87.8° C]).
MAIN – Indicates the status of main door is closed.
LINT – Indicates the lint drawer is closed.
FUSE – Indicates the status of the control voltage after
POWER ON button has been pressed.
Outputs (Green L.E.D.)
All indications are with L.E.D. lit
AUX – This is for a spare output to be programmed.
STEAM – Indicates the status of the steam injection output.
_HEAT – Indicates the status of the heat output.
AIR – Indicates the status of the air jet output.
REV – Indicates the status of the tumbler reverse direction
output.
If the request to tumble the drum in the reverse direction is
made, then the L.E.D. is ON.
FWD – This L.E.D. will indicate the status of the tumbler
forward direction output.
FAN – This L.E.D. will indicate the status of the fan output.