Press key for increase or decrease the speed with 1HZ
increment .
Press key to select the digit for quick setting.
Press to save the setting value.
0 : Lock 1 : Unlock
Function to prevent inadequate setting.
To change the contents data of CD , set CD01=1 and press first.
To lock the data set CD01=0 and press .
CD02 value corresponds to the
time of acceleration from 0 to 50/
60HZ.(For 120Hz. setting, the
arrival time to 120Hz is double.)
F
60HZ
0.1
6000 TIME(Sec)
First speed setting
CD00
Parameter lock
CD01
Acceleration time 1
CD02
25
Setting Range 0 or 1
Default Value 0
Setting Range 0.1 ~ 6000.0Sec
Default Value 10.0Sec
Setting Range 0.00 ~ 400.00HZ
60HZ region 60.00HZ
50HZ region 50.00HZ
ENTER
ENTER
ENTER