Computer command message inverter address=52, foward run at
60.00HZ
1. RTU
Step 1. Write CD00=60.00HZ(6000=1770H) to AC drive address=52
Computer command message
AC drive response message
Step 2. Write address 100 (64H)=1
Computer command message
AC drive response message
Note : When address 100=1, speed is depended on terminal setting
(CF1, CF2, CF3)
2. ASCII
Step 1. Write CD00(60.00HZ) to inverter address=52
D1
34H
D2
06H
D3
00H
D4
00H
D5
17H
D6
70H
D7
CRCL
D8
CRCH
D1
34H
D2
06H
D3
00H
D4
00H
D5
17H
D6
70H
D7
CRCL
D8
CRCH
63
D1
34H
D2
06H
D3
00H
D4
64H
D5
00H
D6
01H
D7
CRCL
D8
CRCH
D1
34H
D2
06H
D3
00H
D4
64H
D5
00H
D6
01H
D7
CRCL
D8
CRCH
Computer command message AC drive response message
STX 3A STX 3A
D1
Address '3'
Address '4'
33
D1
Address '3'
Address '4'
33
34 34
D2
Function '0'
Function '6'
30
D2
Function '0'
Function '6'
30
36 36