ADTECH9 Series CNC Maintenance Manual
- 113 -
Authority : Super Admin
Default : 0
Effective time : After restarted
Note : Set the filter constant;
If the environment has too much interference, such as rain or thunder,
please set a filter value. Higher value indicates longer test time and high
reliability; 0 indicates no filter;
006 Selection of communication mode (restart)
Range : No User Network Uart All User
Unit : None
Authority : Operation admin or higher
Default : Uart
Effective time : Restart
Note : NetTCP
Uart0
Uart1
NetUDP
Uart3
008 Zeroing soft limit no alarm enables
Range : 0~1
Unit : None
Authority : Operation admin or higher
Default : 0
Effective time : Instant
Note
: No soft limit detection required when zeroing
009 USB disk online processing enable
Range : 0~1
Unit : None
Authority : Operation admin or higher