ADTECH9 Series CNC Maintenance Manual
- 143 -
Range : 0~1
Unit : None
Authority : Super Admin
Default : 1
Effective time : Restart
Note : Pulse command format setting is to configure the mode of output pulse.
The compatible command format of the motor driver should be known in
advance.
0 Pulse + pulse
1 Pulse + direction
025 X Pulse Logic Dir Mode (restart)
Y Pulse Logic Dir Mode (restart)
Z Pulse Logic Dir Mode (restart)
4 Pulse Logic Dir Mode (restart)
B Pulse Logic Dir Mode (restart)
C Pulse Logic Dir Mode (restart)
Range : 0~1
Unit : None
Authority : Super Admin
Default : 1
Effective time : Restart
Note : Set pulse direction; if the controller direction is reverse to actual driver
direction, please modify this parameter to adjust the rotation direction of
motor.
026 X Ext Home ELevel
Y Ext Home ELevel
Z Ext Home ELevel
A Ext Home ELevel
B Ext Home ELevel
C Ext Home ELevel
Range : 0~1