ADTECH9 Series CNC Maintenance Manual
- 125 -
Effective time : Instant
Note : Ask: when the system is restarted, it asks whether to execute home
operation; press the [EOB] button to execute.
Auto: when the system is restarted, it executes home operation
automatically.
058 Spindle brake delay (ms)
Range : 0~60000
Unit : Second
Authority : Operation admin
Default : 1000
Effective time : Instant
Note : Used to set the delay between actions of the spindle brake switch
059 This parameter is invalid currently
Range :
Unit :
Authority : Operation admin
Default :
Effective time : Instant
Note : This parameter is invalid currently.
060 4 axis max rotate speed
Range : 1~500
Unit :
Authority : Operation admin
Default : 50
Effective time : Instant
Note : When P1.018 is set to (Angle X Y Z space angle optimization), set the
maximum rotation speed when the fourth axis A is the rotation axis.
061 Handwheel encoder dir