4-184 ADAM 4000 Series User's Manual
4080, 4080D
Command Set
$AA5NS
Name Start/Stop Counter
Description Request the addressed counter/frequency module to start or
stop the counting for a counter 0 or counter 1.
Syntax $AA5NS(cr)
$ is a delimiter character.
AA (range 00-FF) represents the 2-character hexadecimal
address of counter/frequency module that you want to interro-
gate.
5 identifies the Start/Stop Counter command
N determines the counter that should be enabled or disabled.
N = 0 represents counter 0
N = 1 represents counter 1
S represents the counter status.
S = 0 stops counting
S = 1 starts counting
(cr) is the terminating character, carriage return (0Dh)
Response !AA(cr) if the command is valid. There is no response if the
module detects a syntax or communication error, or if the
specified address does not exist.
! is a delimiter character indicating the command was valid.
AA (range 00-FF) represents the 2-character hexadecimal
address of a counter input module.
(cr) is the terminating character, carriage return (0Dh).
Example command: $06501(cr)
response: !06(cr)
The command requests the counter/frequency module at
address 06 to start counter 0. The addressed module replies
with its address to indicate the command has been executed
and counter 0 has started.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Advantech Adam 4000 Series and is the answer not in the manual?

Advantech Adam 4000 Series Specifications

General IconGeneral
BrandAdvantech
ModelAdam 4000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals