Report Duress in EM Card Operation
The Duress Codes are Prime User Codes in the system. In the “EM Card + Secondary User Code”
or “EM Card + Common User Code” operation, they can be used to replace the “Secondary User
Code” or the “Common User Code” to operate the specific output and report a duress alarm event.
Programming is not required. The system has the function automatically while Duress Code exists.
Operation : Taking Duress Code 3 3 6 9 in Group 1 for Output 1 As Example
(a) (b) (c)
a) Read the EM card. Two-beep confirms the reading and 30 seconds waiting time is given for the
entry of Duress Code, the Amber LED keeps flashing
b) Key in the Duress Codes 3 3 6 9 for operating Output 1
c) Confirm it with the key. Output 1 activates in a normal way and the Duress Output also
activates to report Duress Event to an alarm system if connected.
NOTE: Duress Event can not be reported with EM Card alone. User can only directly use Duress
Read Card
Code to open the door and report duress event in emergency