9
Clamp-On Harmonic Probe Model
CREST FACTOR (CF)
Range: 1.00 to 10.00
Resolution: 0.01
Minimum Input: >5 V or >5 A
Accuracy (40 to 70 Hz):
1.00 to 3.50: 2% ± 2 cts
3.51 to 5.99: 5% ±2 cts
6.0 to 10.0: 10% ±2 cts
Display: Digital: CF, Bar graph: True RMS (A or V)
FREQUENCY (HZ)
Range: 0.5 Hz to 20,000 Hz
Minimum Input: 2 A or 2 V
Accuracy: 0.5 Hz to 999.9 Hz: 0.1% R ± 2 cts
1000 Hz to 9999 Hz: 0.2% R ± 2 cts
10 kHz to 20 kHz: 0.5% ± 2 cts
Display: Digital: Hz, Bar graph: DC (A or V), True RMS (A or V)
GENERAL SPECIFICATIONS
Battery: 4 x 1.5 V “AA” alkaline (NEDA 15A, IEC LR6)
Life: approx. 40 hrs continuous use
Dimensions: 10.8 x 4 x 2" (275 x 103 x 52 mm)
Weight: 1.5 lbs (670 g)
Display: Quadriplexed LCD, dual digital display (10 mm, 5 mm),
4 digits 10,000 counts, 31-segment bar graph
Temperature:
Operating: -10° to 55°C (14° to 131°F)
Storage: -40° to 70°C (-40° to 158°F)
Humidity:
Operating: 0 to 90% RH to +40°C (75% RH @ +55°C)
Storage: 0 to 95% RH