19
IREPPY - 1404 - 4238051_01
RePuro
100 170 250
250R
350
350R
450
450R
550
550R
650
650R
 m
3
/h 100 170 250 350 450 550 650
 Pa 85 20 195 133 100 120 70
Winter recovery eciency % 94,4 91,2 91,9 89,4 90,3 88,6 87
Recovered heang capacity W 957 1573 2329 3171 4118 4940 5734
Winter recovery eciency (*) % 90,6 85,3 86,3 82,2 83,7 81 78,4
Recovered heang capacity (*) W 601 963 1433 1910 2500 2957 3386
Summer recovery eciency % 90,6 85,3 86,4 82,2 83,7 81 78,5
Recovered cooling capacity W 180 289 430 573 750 887 1015
 m
3
/h 75 125 150 200 300 350 450
 Pa 135 110 331 376 210 300 270
Winter recovery eciency % 95,7 93,2 94,8 93,3 93 92,1 90,3
Recovered heang capacity W 728 1181 1441 1891 2830 3267 4118
Winter recovery eciency (*) % 92,7 88,6 91,1 88,6 88,2 86,6 83,7
Recovered heang capacity (*) W 462 735 908 1177 1758 2014 2500
Summer recovery eciency % 92,7 88,6 91,2 88,7 88,3 86,7 83,7
Recovered cooling capacity W 138 220 272 353 527 604 750
 m
3
/h 50 75 75 100 150 175 200
 Pa 185 210 426 526 310 430 485
Winter recovery eciency % 97 95,7 97,2 96,4 96,2 95,7 95,1
Recovered heang capacity W 492 728 739 977 1463 1697 1928
Winter recovery eciency (*) % 95 92,7 95,3 93,9 93,6 92,7 91,7
Recovered heang capacity (*) W 315 462 475 623 932 1077 1218
Summer recovery eciency % 95 92,7 95,3 93,9 93,6 92,7 91,7
Recovered cooling capacity W 95 138 142 187 280 323 365
Weight kg 25 25 48 48 55 55 55
Maximum power input W 45 65 160 180 220 280 360
Pre-heater element power input (ver-
sions R)
W 500 500 500 500 500 500 500
Power supply V ~ Hz 230 ~ 50
* Winter recovery
condion
EN 308
Extract air
25°C D.B.
27% R.H.
Supply air
5°C D.B.
50% R.H.
Winter recovery
condion
Extract air
20°C D.B.
50% R.H.
Supply air
-10°C D.B.
80% R.H.
The available pressure may change
from the nominal due to the an-freeze
control
Summer recovery
condion
Extract air
26°C D.B.
50% R.H.
Supply air
32°C D.B.
50% R.H.
(1) (2) Performances refer to condions different to the nominal conditions
Model  
RePuro100 - RePuro170
RePuro250 - RePuro350
RePuro450 - RePuro550 - RePuro650
-10°C +50°C
RePuro250R - RePuro350R
RePuro450R - RePuro550R - RePuro650R
-15°C +50°C
8. TECHNICAL DATA