27
IREPPY - 1404 - 4238051_01
0
100
200
300
400
500
600
700
0 50 100 150 200 250 300 350
[m³/h]
RePuro350
[Pa]
66dB(A)
62dB(A)
57dB(A)
70dB(A)
RePuro350 - Sound power output at supply opening
Air ow
Available stac pressure
Sound power
Air ow curve - Available stac
pressure
0
100
200
300
400
500
600
700
0 50 100 150 200 250 300 350
RePuro350
[m³/h]
[Pa]
66dB(A)
62dB(A)
57dB(A)
70dB(A)
RePuro350 - Sound power output at intake opening
Air ow
Available stac pressure
Sound power
Air ow curve - Available stac
pressure
RePuro350 - Heat recovery efficiency *
0 50 100 150 200 250 300 350
[m³/h]
RePuro350
82
84
86
88
90
92
94
96
98
100
%
Air ow
Ecienza %
* Recovery
eciency
(winter)
EN 308
Extract air
25°C db
27% RH
Supply air
5°C db
50% RH
Supply air ow
=
Intake air ow