10
LIMITED WARRANTY
Aermotor warrants to the original consumer of the products listed below, that they will be free from defects in material and work-
manship for the Warranty Period from the date of original installation or manufacture as noted.
Product Warranty Period
Jet pumps, small centrifugal pumps, whichever occurs first:
submersible pumps and related accessories 1 year from date of original installation, or
2 years from date of manufacture
Hydro-Flow Filters 1 year from date of purchase
Fibrewound Tanks 5 years from date of original installation
Steel Pressure Tanks 5 years from date of original installation
Epoxy-Lined Tanks 3 years from date of original installation
Sump/Sewage/Effluent Products 1 year from date of original installation, or
2 years from date of manufacture
Our warranty will not apply to any product that has been subject to negligence, misapplication, improper installation or mainte-
nance. In the event a three phase submersible motor is operated with single phase power through a phase converter, or if three-
leg ambient compensated, extra-quick trip overload relays of recommended size are not used, our warranty is void.
Buyer’s only remedy and Aermotor’s only duty is to repair or replace defective products (at Aermotor’s choice). Buyer agrees to
pay all labor and shipping charges associated with this warranty and to request warranty service through the installing dealer as
soon as a problem is discovered. If warranty service is requested more than 30 days after the Warranty Period has ended, it will
not be honored.
AERMOTOR SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSO-
EVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WAR-
RANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE WARRANTY PERIOD PROVIDED HEREIN.
Certain states do not permit the exclusion or limitation of incidental or consequential damages or the placing of limitations on the
duration of an implied warranty, therefore, the limitations or exclusions herein may not apply. This warranty sets forth specific legal
rights and obligations, however, additional rights may exist, which may vary from state to state.
Supersedes all previous publications.
Aermotor, 293 Wright St., Delavan, WI 53115
TROUBLE AND CAUSE REMEDY
FAILURE TO PUMP
1. Pump not properly primed. 1. Make sure pump casing and suction line are full of water.
See priming instructions.
REDUCED CAPACITY AND/OR HEAD
1. Air pockets or leaks in suction line. 1. Check suction piping.
2. Clogged impeller. 2. Remove and clean.
PUMP LOSES PRIME
1. Air leaks in suction line. 1. Check suction piping.
2. Excessive suction lift and operating 2. Move pump nearer to water level.
too near shut-off point.
3. Water level drops while pumping, 3. Check water supply. Add length of pipe to suction
uncovering suction piping. to keep submerged end under water.
MECHANICAL TROUBLES AND NOISE
1. Bent shaft and/or damaged bearings. 1. Take motor to authorized motor repair shop.
2. Suction and/or discharge piping not 2. See that all piping is supported to relieve strain
properly supported and anchored. on pump assembly.
TROUBLE - CAUSES AND REMEDY