35
in.xm
TM
accessories corrective actions
P3 - ER / P4 - ER / P5 - ER
Pump not responding
• Make sure the Pump is connected properly.
• Manually change output status (on/off) of the Pump.
• Reset spa pack.
• If error does not clear, problem is probably with the Pump.
It will need to be replaced.
• If the Pump is replaced, a new learning routine must be
performed (see procedure page 15).
CP - ER
Circulation Pump not responding
• Make sure Circ. Pump is connected properly.
• Manually change output status by changing set point.
• Reset spa pack.
• If error does not clear, problem is probably with CP.
It will need to be replaced.
• If the CP is replaced, a new learning routine must be performed
(see page 15).
Note: If the spa is equipped with an in.k600™ menu driven, the learned current value can be verifi ed (see "viewing current management
data" section for more details). Furthermore, if the current value learned by the in.xm™ spa control is not appropriate, it can trigger false
Pump-ER error codes.