accessories corrective actions
P3 - ER / P4 - ER / P5 - ER
Pump not responding
Make sure the Pump is connected properly.
Manually change output status (on/off) of the Pump.
Reset spa pack.
If error does not clear, problem is probably with the Pump.
It will need to be replaced.
If the Pump is replaced, a new learning routine must be
performed (see procedure page 15).
CP - ER
Circulation Pump not responding
Make sure Circ. Pump is connected properly.
Manually change output status by changing set point.
Reset spa pack.
If error does not clear, problem is probably with CP.
It will need to be replaced.
If the CP is replaced, a new learning routine must be performed
(see page 15).
Note: If the spa is equipped with an in.k600 menu driven, the learned current value can be veri ed (see "viewing current management
data" section for more details). Furthermore, if the current value learned by the in.xm™ spa control is not appropriate, it can trigger false
Pump-ER error codes.