D - Line Voltage Conversion
70
Install the Correct Line Fuse
Unscrew the line fuse cap from the rear panel and install the correct fuse.
For 100/120 Vac operation: F4A; part number 2110-0055
For 220/230 Vac operation: F2A; part number 2110-0002
Mark the voltage setting that the unit has been set to on the rear panel label.
Close the Unit
Replace the outer cover.
Reconnect the power cord and turn on the unit.
List of Fuses
F500 2110-0055 1 Fuse, F4A, 250V (for 100/120 Vac input)
F500 2110-0002 1 Fuse, F2A, 250V (for 220/230 Vac input)
F300 2110-0712 1 Fuse, sub-min, M4A, 125V
F301 2110-0712 1 Fuse, sub-min, M4A, 125V
F302 2110-0697 1 Fuse, sub-min, M15A, 32V (66332A, 6632B, 6633B)
F302 2110-0685 1 Fuse, sub-min, M7A, 125V (6634B)
F303 2110-0697 1 Fuse, sub-min, M15A, 32V (66332A, 6632B, 6633B)
F303 2110-0685 1 Fuse, sub-min, M7A, 125V (6634B)
F304 2110-0699 1 Fuse, sub-min, M5A, 125V
F305 2110-0777 1 Fuse, M8A, 32V (66332A, 6632B, 6633B)
F305 0811-3776 1 Res Fusible 0.5 Ohm 5W (6634B)
F310 2110-0025 1 Fuse, M15A, 32V (6631B)