1 – Quick Reference
14
SCPI Programming Commands - At a Glance
NOTE Some [optional] commands have been omitted for clarity. Refer to the Programming
Guide for a complete description of all programming commands.
ABORt SENSe
CALibrate :CURRent :RANGe <n>
:CURRent [:SOURce] [:POSitive] :DETector ACDC | DC
1
:NEGative :FUNCtion “VOLT” | “CURR”
1
:MEASure :LOWRange :SWEep :OFFSet :POINts <n>
1
:AC
1
:POINts <n>
:DATA <n> :TINTerval <n>
:LEVel P1 | P2 | P3 | P4 :WINDow HANN | RECT
:PASSword <n> [SOURce:]
:SAVE CURRent [:LEVel] [:IMMediate] <n>
:STATe <bool> [, <n>] :TRIGgered <n>
:VOLTage [:DC] :PROTection :STATe <bool>
:PROTection DIGital :DATA <n>
DISPlay :FUNCtion RIDF | DIG
[:STATe] <bool> VOLTage [:LEVel] [:IMMediate] <n>
:MODE NORMal | TEXT :TRIGgered <n>
:TEXT <display_string> :ALC :BANDwidth? | :BWIDth?
INITiate :PROTection <n>
[:IMMediate] :SEQuence[1|2
1
] STATus
:NAME TRANsient | ACQuire
1
:PRESet
:CONTinuous :SEQuence[1], <bool> :OPERation [:EVENt]?
:NAME TRANsient, <bool> :CONDition?
MEASure | FETCh
2
:ENABle <n>
:ARRay :CURRent?
1
:NTRansition <n>
:VOLTage?
1
:PTRansition <n>
[:SCALar]:CURRent[:DC]? :QUEStionable [:EVENt]?
:ACDC?
1
:CONDition?
:HIGH?
1
:ENABle <n>
:LOW?
1
:NTRansition <n>
:MAX?
1
:PTRansition <n>
:MIN?
1
SYSTem
:VOLTage [:DC]? :ERRor?
:ACDC?
1
:LANGuage SCPI | COMPatibility
:HIGH?
1
:VERSion?
:LOW?
1
:LOCal
:MAX?
1
:REMote
:MIN?
1
:RWLock
OUTPut TRIGger
[:STATe] <bool> [,NORelay] :SEQuence2 | :ACQuire [:IMMediate]
1
:DFI [:STATe] <bool> :COUN t :CURRent <n>
1
:SOURce QUES | OPER | ESB | RQS | OFF :VOLTage <n>
1
:PON :STATe RST | RCL0 :HYSTeresis:CURRent <n>
1
:PROTection :CLEar :VOLTage <n>
1
:DELay <n> :LEVel :CURRent <n>
1
:RELay [:STATe] <bool>
3
:VOLTage <n>
1
:POLarity NORM | REV
3
:SLOPe :CURRent POS | NEG | EITH
1
:RI :MODE LATCHing | LIVE | OFF
:VOLTage POS | NEG | EITH
1
:SOURce BUS | INTernal
1
[:SEQuence1 | :TRANsient] [:IMMediate]
1
Not available on Agilent 6631B - 6634B :SOURce BUS
2
Fetch commands not available on Agilent 6631B – 6634B :SEQuence1 :DEFine TRANsient
3
Not available on Agilent 6631B
:SEQuence2 :DEFine ACQuire
1

Table of Contents

Other manuals for Agilent Technologies 6634B

Questions and Answers:

Agilent Technologies 6634B Specifications

General IconGeneral
BrandAgilent Technologies
Model6634B
CategoryPower Supply
LanguageEnglish

Summary

Warranty Information

Warranty Coverage and Limitations

Covers warranty terms, exclusions, and remedies.

Safety Summary

General Safety Precautions

Covers general, environmental, power, grounding, and hazardous operation warnings.

Safety Symbols and Warnings

Understanding Safety Symbols

Explains symbols and the meaning of WARNING/CAUTION.

Declaration of Conformity

Compliance Standards and Information

Details manufacturer, EMC, and safety standards.

Acoustic Noise Information

Manufacturer's Noise Declaration

States sound pressure levels as per German directive.

Printing History

Manual Revision History

Lists updates and changes made to the manual.

Quick Reference

DC Source Overview

Introduces the instrument models and their capabilities.

Quick Reference - 1

The Front Panel - At a Glance

Identifies and describes front panel components.

Quick Reference - 1

Front Panel Number Entry

Methods for entering numerical values.

Quick Reference - 1

Front Panel Annunciators

Explains status indicators.

Immediate Action Keys

Describes keys with instant function.

Quick Reference - 1

Front Panel Menus - At a Glance

Overview of menu commands.

Quick Reference - 1

SCPI Programming Commands Summary

Lists common SCPI commands.

Quick Reference - 1

The Rear Panel - At a Glance

Identifies rear panel connectors.

General Information

Document Orientation and Getting Started

Explains manual structure and task guidance.

General Information - 2

Safety Considerations

Safety aspects of the instrument class.

Options and Accessories

Lists available options and accessories.

General Information - 2

Product Description and Capabilities

Details the instrument's features and functions.

Remote Programming Interface

How to program remotely via GPIB/RS-232.

General Information - 2

Output Characteristic Explained

Behavior in CV and CC modes.

Installation

Inspection, Packaging, and Cleaning

Initial checks and maintenance.

Items Supplied

Lists included user-replaceable items.

Installation - 3

Location and Mounting Options

Placement, bench, and rack mounting.

Installation - 3

Input and Output Connections

Connecting power and loads.

Wire Considerations and Ratings

Load wire selection for stability and safety.

Installation - 3

Voltage Drops and Multiple Loads

Managing voltage drops and multiple load connections.

Installation - 3

Remote Sense Connections and Leads

Setting up remote sensing.

Installation - 3

Stability and OVP Considerations

Ensuring stability and understanding OVP.

Installation - 3

Fast/Normal Operation Modes

Using fast and normal modes.

Capacitive and Inductive Loading

Effects of load types on stability.

Installation - 3

INH/FLT and Digital I/O Connections

Using inhibit/fault and digital I/O ports.

Installation - 3

Controller Interface Connections

Connecting via GPIB and RS-232.

Turn-On Checkout

Introduction and Keypad Usage

Overview of checkout and keypad functions.

Turn-On Checkout - 4

Checkout Procedure Steps

Step-by-step guide for initial checkout.

Turn-On Checkout - 4

Troubleshooting: Errors and Fuses

Addresses error messages and line fuse issues.

Front panel Operation

Introduction and Front Panel Description

Chapter overview and front panel layout.

5 - Front Panel Operation

Front Panel Controls and Indicators

Details display, annunciators, keys, and connectors.

Front Panel Operation - 5

System Keys Explained

Detailed functions of system keys.

5 - Front Panel Operation

Function, Immediate Action, and Scrolling Keys

Describes key types and navigation.

Front Panel Operation - 5

Metering Keys Functionality

How to use metering keys for measurements.

5 - Front Panel Operation

Output Control Keys Usage

Controlling output functions and protection.

Front Panel Operation - 5

Entry Keys Functionality

Detailed explanation of keypad entry.

5 - Front Panel Operation

Front Panel Programming Examples

Practical examples for setting voltage, current, and output.

Front Panel Operation - 5

Querying Protection and Front Panel Measurements

Checking protection and taking measurements.

5 - Front Panel Operation

Front Panel Pulse Measurement Parameters

Details on measuring waveform parameters.

Front Panel Operation - 5

Programming the Digital Output Port

Configuring the digital output port.

5 - Front Panel Operation

Output Relay Programming and Interface Setup

Controlling relays and setting up GPIB/RS-232.

Front Panel Operation - 5

Saving and Recalling Operating States

Managing instrument states.

Specifications

Performance Specifications

Warranted performance parameters.

A - Specifications

Supplemental Characteristics

Typical performance characteristics.

Verification and Calibration

Equipment Required for Verification

Necessary equipment for tests.

B - Verification and Calibration

Performing the Verification Tests

Steps for operational verification.

Verification and Calibration - B

Voltage and Current Accuracy Tests

Verifying voltage and current programming/measurement.

B - Verification and Calibration

Current Measurement and Sink Tests

Verifying low-range current and sink measurements.

Verification and Calibration - B

Verification Test Records

Tables for recording test results for different models.

Verification and Calibration - B

Performing the Calibration Procedure

Steps to perform calibration.

Front Panel Calibration Menu

Commands used in the calibration menu.

B - Verification and Calibration

Calibration Mode, Voltage, and OVP Calibration

Activating calibration and calibrating voltage/OVP.

Verification and Calibration - B

Current and Measurement Calibration

Steps for current and measurement calibration.

B - Verification and Calibration

AC Current Calibration, Saving Constants, and Errors

AC calibration, saving, and error messages.

Verification and Calibration - B

Changing Calibration Password and GPIB Calibration

Password management and GPIB calibration.

Error Messages

Error Number List and Categories

Lists error numbers, descriptions, and categories.

C - Error Messages

Error Categories Explained

Details Command, Execution, System, and Query errors.

Error Messages - C

Specific Error Codes

Lists selftest and device-dependent error codes.

Line Voltage Conversion

Opening Unit and Transformer Configuration

Steps to open unit and adjust transformer.

D - Line Voltage Conversion

Fuse Installation and Unit Reassembly

Installing correct fuse and closing the unit.