EasyManuals Logo

Agilent Technologies 8960 Series Programming Guide

Agilent Technologies 8960 Series
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
34
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Proguide\Chapters\prog_prog_guide_step4.fm
Step 4: Establish an Active Link with Mobile Station
Example 1. Command Syntax:
CALL:CONNected[:STATe]?
Using the Call Connected State Query for Call Connect Synchronization The call-connected-state query only
hangs if the call is in a transitory state, otherwise it immediately returns a 1 (Connected state) or a 0 (Idle state). At the
start of a call connect process the call state is Idle. Sending call-connected-state query at the start of a call connect
process could immediately return a zero if the query is satisfied before the connection process has started (that is, moved
from the Idle state into one of the transitory states). For correct call connect synchronization it is necessary that the
query be temporarily held off until after the call connect process has started. A call-state-change-detector is provided
which can be used to temporarily hold off the query from returning an answer until the appropriate state change has
occurred.
Call Connected Arm Command The call-connected-arm command is used to ‘arm’ the
call-state-change-detector.
Example 2. Command Syntax:
CALL:CONNected:ARM[:IMMediate]
If the call-state-change-detector is armed when a call-connected-state query is received, the reply is held off
until the call-state-change-detector is disarmed. The call-state-change-detector is disarmed upon a state
change from any of the transitory states to the Idle or Connected state.
The call-state-change-detector is not disarmed by a state change from Idle to any of the transitory states, from
Connected to any of the transitory states, nor is it disarmed by any transitions from Idle to Idle, or Connected
to Connected. These restrictions ensure that when the call-connected-state query returns an answer:
the connect process has started since the call state must have moved from Idle to one of the transitory
states
AND
the connect process has finished since the call state has moved from a transitory state to either the Idle or
Connected state.
The arm state of the change detector can be queried with the call-connected-arm-state query command. This
query never hangs and immediately returns a 1 if the change detector is armed and a 0 if it is not armed. The
command is:
Example 3. Command Syntax:
CALL:CONNected:ARM:STATe?

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8960 Series and is the answer not in the manual?

Agilent Technologies 8960 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model8960 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals