76 Chapter 5
Options and Accessories
Options
060 Low Emission Option 060 provides reduced radiated and conducted emissions to
comply with EN55011 Class B requirements. The reduced
emissions applies during ac operation only.
Option 060 is incompatible with TV Trigger (Option B7B) and
75 input impedance (Option 1DP).
UKB Low Frequency Extension Option UKB extends the frequency range of the analyzer on the
low end to 100 Hz when DC coupling is selected. This option
requires installation of Option 1DR and is only available on ESA
models E4402B, E4404B, E4405B, and E4407B.
1DR Narrow Resolution
Bandwidth
This option provides additional narrow resolution bandwidths of
10 Hz, 30 Hz, 100 Hz, and 300 Hz and 200 Hz EMI. These
bandwidths improve the analyzer sensitivity and allow you to
resolve closely spaced signals. If high stability frequency
reference (Option 1D5) is also installed then 1 Hz and 3 Hz
resolution bandwidth filters are available.
1DS Preamplifier The preamplifier improves the analyzers sensitivity (lowers the
noise floor) by approximately 16 dB.
B74 RF and Digital
Communications Hardware
Option B74 includes:
RF Communications Hardware (Option B7E),
Digital Signal Processing and Fast ADC (Option B7D),
Time-Gated Spectrum Analysis (Option 1D6),
Memory Extension (Option B72),
High Stability Frequency Reference (Option 1D5),
Preamplifier (Option 1DS),
Narrow Resolution Bandwidth (Option 1DR).
These options are required for optimum performance of the
cdmaOne (Option BAC) or GSM measurement personality
(Option BAH).
B75 Performance Bundle Option B75 provides:
RF Preamplifier (Option 1DS)
Narrow Resolution Bandwidths (Option 1DR)
High Stability Frequency Reference (Option 1D5)
Refer to Options 1DS, 1DR, and 1D5 for details.
This option is only available at time of purchase.
B7E RF Communications
Hardware
Option B7E provides the communications hardware required for
many digital communication measurements. Option B7E must be
ordered with Option B7D (digital signal processing and fast
ADC) and Option 1D5 (high stability frequency reference). This
provides burst carrier trigger capability.
Option
Number
Name Description

Table of Contents

Other manuals for Agilent Technologies E4404B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies E4404B and is the answer not in the manual?

Agilent Technologies E4404B Specifications

General IconGeneral
BrandAgilent Technologies
ModelE4404B
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals