Hard disk drive options
Option 019 Standard hard disk drive
Option 019 provides a fi xed hard disk drive. The removable
disk drive is not available.
Option 017 Removable hard disk drive
Option 017 provides a removable hard disk drive. You can
remove or replace the hard disk drive for secure area
operations. If a spare disk is needed, order E5071CU-018
hard disk drive kit.
Certification options
Option 1A7 ISO 17025 compliant calibration
Option 1A7 provides a complete set of measurements
which test the unit to manufacturer’s published specifi -
cations. Includes calibration label, ISO 17025 calibration
certifi cate, and data report, and measurement uncertainties
and guardbands on all customer specifi cations. Conforms
to ISO 17025 and ISO 9001.
Option A6J ANSI Z540 compliant calibration
Option A6J provides a complete set of measurements
which test the unit to manufacturer’s published specifi ca-
tions. Includes pre- and post-adjustment data and measure-
ment uncertainty information compliant with the ANSI/
NCSL Z540 standard.
1. When using an ECal module with MWA calibration wizard, a 4-port ECal module (i.e. N4431B, N4433A) is required.
ENA Network Analyzer (E5071C)
Additional software options
Option 010 Time domain
Option 010 enables the ENA to view refl ection and trans-
mission responses in the time domain. Use time domain to
tune fi lters, gate out the response of fi xtures and cables,
characterize the impedance of transmission lines, and
more.
Option 008 Frequency offset mode
Option 008 enables the ENA to set the receiver frequencies
independently from where the source frequency is tuned.
This ability is important for harmonic distortion measure-
ments and for measuring frequency converting devices
such as mixers and converters. Advanced calibration tech-
niques for the ENA, such as scalar mixer calibration (SMC)
or vector mixer calibration (VMC), require this option.
Option 790 Measurement Wizard Assistant
Option 790 provides a simple measurement procedure
setup for the 4-port ENA with a multiport test set such as
the E5092A. The software delivers an easy-to-use mea-
surement wizard programs including a calibration wizard
setup
1
, which reduces operation time for complicated,
time-consuming multiport measurements.
Time base options
Option UNQ Standard stability time base
Option UNQ provides following stability:
CW accuracy: ±5 ppm (specifi cation)
Source stability: ±5 ppm (5 °C to 40 °C typical)
Option 1E5 High stability time base
Option 1E5 provides the following stability:
CW accuracy: ±1 ppm (specifi cation)
Source stability: ±0.05 ppm (5 °C to 40 °C typical),
± 0.5 ppm/year