SCPI Commands Appendix B
Model N6705 User’s Guide 187
SCPI Command Description
:CCOMpensate <Bool>, (@chanlist)
Enables/disables the capacitive current compensation
[:UPPer] <NRf+>, (@chanlist)
Selects the current measurement range
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)
[:UPPer] <NRf+>, (@chanlist)
Sets the internal data log current range
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)
:CURRent <Bool>, (@chanlist)
Enables/disables current data logging
Enables/disables min/max data logging
:VOLTage <Bool>, (@chanlist)
Enables/disables voltage data logging
Positions the data log markers
Sets trigger offset as a percent from start of data log duration
Sets the interval between samples (replaces TINTerval)
Sets the duration of the data log in seconds
Sets the interval between samples (for backward compatibility)
[:UPPer] <NRf+>, (@chanlist)
Sets the internal data log voltage range
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)
[:UPPer] <NRf+>, (@chanlist)
Sets the external data log current range
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)
:CURRent <Bool>, (@chanlist)
Enables/disables external current data logging
:MINMax <Bool>, (@chanlist)
Enables/disables external min/max current data logging
:VOLTage <Bool>, (@chanlist)
Enables/disables external voltage data logging
:MINMax <Bool>, (@chanlist)
Enables/disables external min/max voltage data logging
:PERiod <NR1>, (@chanlist)
Sets the integration time of the external data logging
[:UPPer] <NRf+>, (@chanlist)
Sets the external data log voltage range
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)
:FUNCtion “VOLTage”|”CURRent” | “NONE”, (@chanlist)
Enables the measurement function (for backward compatibility)
:CURRent <Bool>, (@chanlist)
Enables/disables current measurements (replaces FUNCtion)
:VOLTage <Bool>, (@chanlist)
Enables/disables voltage measurements (replaces FUNCtion)
:INPut MAIN | AUXiliary, (@chanlist)
Selects the voltage measurement input (only on N6781A)
:GAIN? 8 | 0.0039, (@chanlist)
Queries the LSB weight of the histogram (N6781A, N6782A)
:OFFSet? 8 | 0.0039, (@chanlist)
Queries the weight of the histogram (N6781A, N6782A)
Queries the values of the bin ranges (N6781A, N6782A)
[:UPPer] <NRf+>, (@chanlist)
Sets the measurement range of the histogram (N6781A, N6782A)
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)