9. More Functions & Setting Tips
Delay Start Function
1. Turn on the switch, display light up.
2. Press on/off button, then press setting button then enter delay start timer
setting, the timer range is 0-48hours. There’s beep sound reminder when timer
finishes the count down.
Temperature
Calibration
1. When the machine is stop working, pressing the on/off button for 3 second until
the page show current temperature.
2. Pressing “+” and “- at the same time active the C1 temperature calibration,
press on/off button for confirmation the setting. The setting range is from +10
to -10℃.
Boiling Point
Compensation Setting
1. When the machine is working, pressing the on/off button for 5 seconds until
the page show current temperature.
2. Pressing “+” and “-” at the same time activates the C1 temperature calibration.
3. Press set button again to active the C2 Boiling point compensation setting. This
adjustment is only effective on temperature above 90, the setting range is 0
- 10℃.
Switching Centigrade /
Fahrenheit
1. Turn on the switch and pressing “+” button for 5 second.
2. Press “+” button to choose the temperature unit, then press on/off button to
confirm.
Wi-Fi Setting Clearance
1. Long pressing setting button for 5 second to clear the phone matched to this
device before.
Matching Wi-Fi
1. Download Tuya App
2. Turn on the switch, Wi-Fi sign is flashing, find out the adding device button on
app.
3. When the app found the device, confirm, and add it, then input your Wi-Fi ID
and password.
4. After input the Wi-Fi ID and password then start to match the device to app till