3 | Product description AHT Cooling Systems GmbH | en
32 / 505 405859_1_0819
3 Product description
3.1 General information
AHT products comply with EU Regulation 1907/2006
(REACH) on the Registration, Evaluation, Authorisation
and Restriction of Chemicals.
Neither refrigerant R-290 nor the blowing agent pen-
tane have an ozone depletion potential (ODP).
R-290 has a very low global warming potential (GWP)
of 3.
3.2 Technical data
Key technical data can be found on the rating plate
(see Rating plate and serial number).
Parameter
Value
External dimensions
See Appliance model over-
view
Appliance weight
See Appliance model over-
view
Airborne noise emit-
ted/emission sound
pressure level
< 70 dB(A)
Refrigerant
Propane (R-290)
M-package tempera-
ture class (product
temperature class)
pursuant to EN ISO
23953-2
L1
Series
Area of use/ op-
erating mode
Selectable ap-
plication
(-)
Deep freezing “-
A1/A2
Customer-specific factory setting when delivered.
Bus system
Parameter
Value
Bus cable
Patch cable CAT 5-S/FTP
Bus system (op-
tional)
PROTOCOL MODBUS RTU
RS-485 2-WIRE
Connection via RJ45
socket/RJ45 connector
Baud rate
19200 bit/s
Data length
8-bit
Parity
None
Stop bit
1
Minimum TimeOut
60 ms
Electrical connection
Parameter
Value
Rated voltage/ rated
frequency
220 - 240 V/50 Hz
Connecting cable
3-pin cable
Minimum cross-sec-
tion for connecting
cables
1.0 mm
2
Mains plug - mains side
Parameter
Value
Plug types
CEE 7/7
Plug types
BS 1363
Appliance plug - appliance side (lEC box)
Parameter
Value
Plug types
IEC 60320-C13
Fusing
See Fusing
Rated
cur-
rent
[A]
Fault
current
[mA]
Type
Tripping
charac-
teristic
Circuit breaker (LS/CB)
16
-
-
C (slow-
acting)
Residual current circuit breaker (FI/RCCB/GFCI)
40
30
G (short-time delay)
A (pulse current-sensitive)/
F (mixed frequency-sensi-
tive)/ B (universal current-
sensitive)
-
Residual current circuit breaker with overcurrent pro-
tection FI-LS/RCBO (alternative to RCCB and CB)
16
30
G (short-time delay)
A (pulse current-sensitive)/
F (mixed frequency-sensi-
tive)/ B (universal current-
sensitive)
C (slow-
acting)
Recommended light colours
Parameter
Value
Cold white
5000 K
Custom deviations possible.
More information: Maintenance service (see
Maintenance services).
3.3 Rating plate and serial number
Observe the information on the rating plate.
The rating plate is a sticker on the back of the appliance.
Information on rating plate
Appliance name and type
Serial number
Climate class*
Rated voltage and frequency
Rate current and consumption
Refrigerant and quantity used
Net content
Date of manufacture
and further technical data
*Examples of climate classes:
Climate class
pursuant to
ISO 23953-2
Ambient tem-
perature [°C]
Relative hu-
midity [%]
3
25
60

Table of Contents

Other manuals for AHT PARIS 185

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AHT PARIS 185 and is the answer not in the manual?

AHT PARIS 185 Specifications

General IconGeneral
BrandAHT
ModelPARIS 185
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals