7 | AC Series - Quick Start Guide
Adding Panels - AC Nio Steps (Continued)
After clicking
+Create
, a pop-up will appear asking if door contacts are being used. Similar to the Auto Add Doors setting, if
Use Door Contacts is checked and a door contact is not connected to the panel, the panel will report the door as being forced open. By
default, the controller will relock the door strike once the door opens. This means when the door reports Open, the door strike will not
unlock. Click
Save
when nished.
Managed will be selected for the door type by default. Give the door a Name and detailed Description. Use the drop-down menu to
select which Panel the door will connect to and select door Port on Panel to select which port it is connected to. Select a Schedule
that the reader will use.
Next, the settings for the reader itself need to be congured. Assign the reader a Name and detailed Description. Select the Wiegand
port the door's card reader will be wired to from in the Port on Panel eld.
Reader Name
Reader Description
Wiegand Port the card reader is wired up to.
Door Name
Detailed Description
Panel for Door
Port for Relay Output.
Door Schedule
Door Holiday Schedule
After the panel has been added, doors must be added to the panel, or renamed if added automatically. To begin adding or
renaming doors, navigate to Hardware, Doors. To add a new door, click
+Add
. If renaming an automatically added door, click the
cogwheel icon.
Adding Doors/Elevators