System Settings (Settings (Station View))
237
4.2. Output Specifications
Configure the settings for output specifications of each station.
4.2.1. Relay Output Specifications
 Output Time [msec / sec] ♦
 Usage
If "New System" is chosen from "Login and registration of the station," the settings for "Usage" 
will be "Door Release" when "Automatically configure door release for all stations?" is enabled.
Description Set the output time of the relay output for each station.
The entry is identical to "Output Time [msec / sec] ♦" ➤ P.248. When the setting is 
changed, "Output Time [msec / sec] ♦" ➤ P.248 will be changed as well.
Settings • 0 (Momentary): Delivers output while Master Station presses "Door Release" button.
• 200-2000 msec (by 200 msec)
• 3-300 sec (by 1 sec)
Default values 200-2000 msec, 400 msec
Description Set the usage of relay output for each station.
The entry is identical to "Usage" ➤ P.248. When the setting is changed, 
"Usage" ➤ P.248 will be changed as well.
Settings • Blank: Not used
• Door Release: Output to release the door.
• Paging Control (Door Station only): Output while paging. Regardless of "
Output 
time" setting, the output is active for the duration of paging audio.
• Contact Input Call / Communication State (Door Station only): Delivers output during 
a call or communication triggered by the contact input.
Default values Blank