Startup
16 3A4180C
Startup
1. Perform Pressure Relief Procedure,
page 12.
2. Turn pressure control to lowest
pressure.
3. Place fluid intake in paint pail. Place
drain tube in waste pail.
4. Turn ON/OFF switch to ON position.
5. Turn pressure control 1/2 turn to start
motor. Allow paint to circulate through
sprayer until paint flows out the drain
tube.
6. Turn prime valve horizontal. Disengage
trigger lock.
ti29463a
ti25129a
ti29464a
ti29462a