Maintenance
2020 Flying Cloud 8-25
25RB Flying Cloud (50 Amp)
Main Circuit, 50 Amp
Circuit 1, 15 Amp
A Water Heater 12.0 Amps
Circuit 2, 20 Amp
B Front Air Conditioner 16.0 Amps
Circuit 3, 15 Amp (GFCI)
C Refrigerator Receptacle 2.7 Amps
D Bathroom Receptacle 1.5 Amps
D Bathroom Receptacle - CSA 1.0 Amps
E RS Nightstand Receptacle 1.5 Amps
E RS Nightstand Receptacle - CSA 1.0 Amps
F Galley Receptacle 1.5 Amps
F Galley Receptacle - CSA 1.0 Amps
G Outside Receptacle 1.5 Amps
G Outside Receptacle - CSA 1.0 Amps
H Galley Endpanel Receptacle 1.5 Amps
H Galley Endpanel Recept - CSA 1.0 Amps
Circuit 4, 20 Amp
J Rear Air Conditioner 16.0 Amps
Circuit 5, 15 Amp
K Microwave Receptacle 12.0 Amps
Circuit 6, 15 Amp
L Converter (Wired Direct) 8.0 Amps
Circuit 7, 15 Amp
M Inverter Receptacle 0.0 Amps
N Inverter 0.0 Amps
P Main Living Area TV Receptacle 0.25 Amps
R Dinette Receptacle 1.5 Amps
R Dinette Receptacle - CSA 1.0 Amps
S Blu-Ray Player Receptacle 0.15 Amps
T Bedroom TV Receptacle 0.25 Amps
DC to AC 1000W Inverter Rated at 8.5 Amp
Inverting
15 Amp Fuse for Overcurrent. Transfer Switch rated
at 15 Amp. UL 458 Tested. ULC