Maintenance
2020 Flying Cloud 8-29
28’ Flying Cloud (50 Amp)
Main Circuit, 50 Amp
Circuit 1, 15 Amp
A Water Heater (Wired Direct) 12.0 Amps
Circuit 2, 20 Amp
B Front Air Conditioner 16.0 Amps
Circuit 3, 20 Amp (GFCI)
C RS Living Area Receptacle 1.5 Amps
C RS Living Area Receptacle - CSA 1.0 Amps
D Dinette Receptacle 1.5 Amps
D Dinette Receptacle - CSA 1.0 Amps
E Outside Receptacle 1.5 Amps
E Outside Receptacle - CSA 1.0 Amps
F Bathroom Receptacle 1.5 Amps
F Bathroom Receptacle - CSA 1.0 Amps
G Fwd CS Bedroom Receptacle 1.5 Amps
G Fwd CS Bedroom Recept - CSA 1.0 Amps
H CS Bedroom NS Receptacle 1.5 Amps
H CS Bedroom NS Recept - CSA 1.0 Amps
J RS Bedroom NS Receptacle 1.5 Amps
J RS Bedroom NS Recept - CSA 1.0 Amps
K Refrigerator Receptacle 2.7 Amps
L Galley Receptacle 1.5 Amps
L Galley Receptacle - CSA 1.0 Amps
Circuit 4, 20 Amp
M Bedroom Air Conditioner 16.0 Amps
Circuit 5, 15 Amp
N Microwave Receptacle 12.0 Amps
Circuit 6, 15 Amp
P Converter (Wired Direct) 8.0 Amps
Circuit 7, 15 Amp
R Inverter Receptacle 0.0 Amps
S Inverter 0.0 Amps
T Blu-Ray Player Receptacle 0.15 Amps
U CS Living Area Receptacle 1.5 Amps
U CS Living Area Receptacle - CSA 1.0 Amps
V Main Living Area TV Receptacle 0.25 Amps
W Bedroom TV Receptacle 0.25 Amps
DC to AC 1000W Inverter Rated at 8.5 Amp
Inverting
15 Amp Fuse for Overcurrent. Transfer Switch rated
at 15 Amp. UL 458 Tested. ULC