ELECTRICAL DATA
Service Manual YBZE DCI 1-A.1 GB 8-1
8. ELECTRICAL DATA
MODEL
YBZE218
YBZE324
YBZE430
Power Supply
To outdoor
1PH-220-240V-50Hz
Max Current, A
12A
21A
21A
Circuit Breaker, A
25A
32A
32A
Power Supply Wiring No. X Cross Section
mm
2
3x2.5 mm
2
3x2.5mm
2
3x2.5mm
2
Interconnecting Cable Model No. X Cross
Section mm
2
4x1.0 mm
2
4x1.0 mm
2
4x1.0 mm
2
NOTE
Power wiring cord should comply with local laws and electrical regulations requirements.