12-18
CONTROL SYSTEM
SM PNXDCI 1-A.1 GB
12.12.2 Outdoor Units SW Parameters:
Model dependent parameters for GC 18 / 21
# Name Single GC 18 Single GC 21
1 MinFreqC 20 20
2 MaxFreqC 85 95
3 MinFreqH 20 26
4 MaxFreqH 95 94
5 NormAccel 1 1
6 NormDecel 1 1
7 Step1Freq 60 60
8 Step2Freq 70 70
9 Step3Freq 90 90
10 OFVL 20 20
11 OFLOWC 60 55
12 OFMEDC 76 70
13 OFMAXC 92 79
14 OFLOWH 60 55
15 OFMEDH 83 70
16 OFMAXH 100 79
17 OFANTESTMODEC 92 83
18 OFANTESTMODEH 100 83
19 OFDelTestMode 28 28
20 CTTOH1 94 94
21 CTTOH2 98 98
22 CTTOH3 102 102
23 CTTOH4 105 105
24 CCROC1 10 11.4
25 CCROC2 10.5 11.8
26 CCROC3 10.8 12.2
27 CCROC4 11.2 12.6
28 DEICT1 60 60
29 DEICT2 36 36
30 DEICT3 6 6
31 ProtFreqLimit 60 60
32 EEVDecierOpen 100 180
33 OptimDeicFreq 90 90
34 EEVMinOperOpenC 50 80
35 EEVMaxOperOpenC 380 380
36 EEVMinOperOpenH 50 60
37 EEVMaxOperOpenH 380 300
38 EEVNormRate 33 33
39 EEVHighRate 12 12
40 EEVMaxOpen 500 500
41 OFLowFreqC 40 35
42 OFMedFreqC 70 55
43 OFLowFreqH 40 40
44 OFMedFreqH 86 60
45 HeaterDisableFlag 0 0
46 DeiceFreqChRV 0 0
47 OATRefC 35 35
48 SUCT Enable 0 0
49 HST Enable 1 1
50 OAT Enable 1 1
51 OATRefH 7 7
52 MinTargCTTC 30 30
53 MaxTargCTTC 95 90
54 MinTargCTTH 40 45
55 MaxTargCTTH 95 90
56 DST 8 8
57 DSTF 12 12
58 OATLimitC 28 28
59 OATLimit1H 6 6
60 OATLimit2H 15 15
61 MaxFreqAsOATC 64 85
62 MaxFreqAsOAT1H 85 80
63 MaxFreqAsOAT2H 60 60
CONTENTS

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Airwell GC 21 DCI and is the answer not in the manual?

Airwell GC 21 DCI Specifications

General IconGeneral
BrandAirwell
ModelGC 21 DCI
CategoryAir Conditioner
LanguageEnglish

Related product manuals