Encryption
Event transmission encryption settings in the SIA protocol. AES 128-bit
encryption is used.
Panic button coordinates
Alarm Restore on ARC
The setting allows you to select when the alarm restore event will be sent
to the CMS: immediately/upon detector restore (by default) or upon
disarming.
Monitoring Station Ping Interval — sets the period for sending test
messages: from 1 minute to 24 hours.
Encryption — if enabled, events and alarms transmitted to the central
monitoring station in SIA format are encrypted.
Encryption key — encryption key of transmitted events and alarms.
Must match the value on the Central Monitoring Station.
Send coordinates — if enabled, the pressing of a panic button in the
app sends the coordinates of the device on which the app is installed
and panic button is pressed, to the central monitoring station.
Learn more
Installers — PRO users settings (installers and representatives of security
companies) of the security system. Determine who has access to your
security system, the rights that are granted to PRO users, and how the
security system noties them about the events.
How to add PRO to the hub