8.1.2 AdvancedConguration
This conguration allows the user to determine which button activates a specic
relay.
1. Open the lid on the receiver (6 TX20 screws).
2. Press the Learn/Erase button until LED 7 is ON. The Learn Mode will be
active for 10 seconds.
a. Press the Learn/Erase button once in order to select relay one (the status
LED will ash once).
b. Press the Learn/Erase button twice in order to activate relay two (the
status LED will ash twice).
c. Press the Learn/Erase button three times in order to activate relay three
(the status LED will ash three times).
3. Press the button that shall be used for activating the selected relay in the
receiver. If the conguration is accepted by the receiver, LED 7 ashes 3
times.
4. Mount the lid on the receiver. Tighten the screws with TX20, torque 2,0
Nm.
8.1.3 ErasingAllTransmittersintheReceiver
1. Open the lid on the receiver (6 TX20 screws).
2. Press the Learn/Erase button until LED 7 is ON. The Learn Mode will be
active for 10 seconds.
3. Press the Learn/Erase button for 5 seconds (until LED 7 is OFF). All trans-
mitters are now erased from the receiver memory.
4. Mount the lid on the receiver. Tighten the screws with with TX20, torque
2,0 Nm.

Other manuals for Åkerströms SESAM 800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Åkerströms SESAM 800 Series and is the answer not in the manual?

Åkerströms SESAM 800 Series Specifications

General IconGeneral
BrandÅkerströms
ModelSESAM 800 Series
CategoryRemote Control
LanguageEnglish

Related product manuals