System Management
7450 ESS OS Basic System Configuration Guide Page 335
both — In the case of both, both a entry in the RMON-MIB logTable and a TiMOS logger
event are generated.
none — In the case of none, no action is taken.
Default both
startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first created. If the
first sample is greater than or equal to the rising threshold value and startup-alarm is equal to rising or
either, then a single rising threshold crossing event is generated. If the first sample is less than or equal
to the falling threshold value and startup-alarm is equal to falling or either, a single falling threshold
crossing event is generated.
Values rising, falling, either
Default either
Configuration example:
cflash-cap-warn cf1-B: rising-threshold 2000000 falling-threshold 1999900 interval 240 rmon-event-
type trap start-alarm either
kb-memory-use-alarm
Syntax kb-memory-use-alarm rising-threshold threshold [falling-threshold threshold] interval
seconds [rmon-event-type] [startup-alarm alarm-type]
no kb-memory-use-warn
Context config>system>thresholds
Description This command configures memory use, in kilobytes, alarm thresholds.
The no form of the command removes the parameters from the configuration.
Default none
Parameters rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current sampled
value is greater than or equal to this threshold, and the value at the last sampling interval was less than
this threshold, a single threshold crossing event will be generated. A single threshold crossing event
will also be generated if the first sample taken is greater than or equal to this threshold and the
associated startup-alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be generated until the
sampled value falls below this threshold and reaches less than or equal the falling-threshold value.
Default 0
Values -2147483648 — 2147483647
falling-threshold threshold — Specifies a threshold for the sampled statistic. When the current sampled
value is less than or equal to this threshold, and the value at the last sampling interval was greater than
this threshold, a single threshold crossing event will be generated. A single threshold crossing event
will also be generated if the first sample taken is less than or equal to this threshold and the associated
startup-alarm is equal to falling or either.