Show Commands
7450 ESS OS Basic System Configuration Guide Page 471
Context show>system
Description This command displays switch fabric information.
Output Switch fabric output — The following table describes switch-fabric output fields for 12-slot and 7-slot
chassis models:.
Sample Output
A:ALA-7# show system switch-fabric
==============================================================================
Switch Fabric
==============================================================================
Slot/Mda Min. Forwarding Capacity Max. Forwarding Capacity
------------------------------------------------------------------------------
1/1 100% 100%
1/2 100% 100%
2/1 100% 100%
2/2 100% 100%
3/1 100% 100%
3/2 100% 100%
4/1 100% 100%
4/2 100% 100%
5/1 100% 100%
5/2 100% 100%
A 100% 100%
B 100% 100%
==============================================================================
A:ALA-7#
A:ALA-12# show system switch-fabric
==============================================================================
Switch Fabric
==============================================================================
Slot/Mda Min. Forwarding Capacity Max. Forwarding Capacity
------------------------------------------------------------------------------
1/1 100% 100%
1/2 100% 100%
2/1 100% 100%
2/2 100% 100%
3/1 100% 100%
Table 35: Show System Switch-Fabric Output Fields
Label Description
Slot/MDA
Displays the fabric slot within a chassis in the system. The CPM cards
and IOM cards cannot be physically inserted into the switch fabric card
slots.