Maintenance Manual –
8242 DECT Handset
8AL 90310 USAA Ed01 6 /18
Or when Vol- key pressed:
Line 4: RFPI in octal
Line 5: RFPI in hex
The line contains the list of base stations identified by the handset as
RPNs of the bases in respect to the signal strength values below. Up to
5 RPNs can be displayed.
This indicates the actual signal strength information (RSSI) to the base
station the current handset is locked to and additional RFPs visible.
RSSI unit is -dBm. The RSSI value increases the closer the base is to the
handset.
If the base could not be detected, the RSSI value will decrease and
after a while the entry will be deleted, if e.g. the dummy-bearer
position has changed or the RFP is unreachable.
Note:
- Long press on * key: Slow/Rapid measurements
- Long press on # key: No Lock / Lock to base
Note : For more detailed information, please refer to “DECT and IP-DECT Engineering Rules and Site
Survey Kit Manual (8AL_90874_USAAed01)”
The site survey is shown together with the normal display, using the top third of the screen area. It is
displayed in all modes: Idle, conversation, etc…