Using Switch Logging Switch Logging Defaults
OmniSwitch AOS Release 8 Network Configuration Guide December 2017 page 36-2
Switch Logging Defaults
The following table shows switch logging default values.
Global Switch Logging Defaults
Quick Steps for Configuring Switch Logging
1 Enable switch logging by using the following command:
-> swlog
2 Specify the ID of the application to be logged along with the logging severity level.
-> swlog appid bridge level warning
Here, the application ID specifies bridging and the severity is set to the “warning” level.
3 Specify the output device to which the switch logging information must be sent.
-> swlog output console
-> show swlog
-> show swlog
Operational Status                 : Running,
File Size per file                 : 100K bytes,
Log Device                         : console flash,
Syslog FacilityID                  : local0(16),
Remote command-log                 : Disabled,
Hash Table entries age limit       : 60 seconds,
Switch Log Preamble                : Enabled,
Switch Log Debug                   : Disabled,
Switch Log Duplicate Detection     : Enabled,
Console Display Level              : debug3,
Parameter Description CLI Command Default Value/Comments
Enabling/Disabling switch logging swlog Enabled
Switch logging severity level swlog appid Default severity level is info. The numeric 
equivalent for info is 6
Enabling/Disabling switch logging 
Output
swlog output Flash Memory and Console
Switch logging file size swlog output 
flash-file-size