FITTED EQUIPMENT
121
Troubleshooting
Any error messages will be displayed on the
Standby Screen. Error messages can be
cleared by removing 12 V supply to the boiler
for 10 secs.
The system is completely dead, the
control panel is blank
Check the 20 mm T3.15 Amp glass fuse in
the boiler. This is located under the lid of the
black plastic service hatch, in a green plastic
fuse holder.
Check the 12 V supply to the boiler, it should
be above 12 V.
Check the 12 V cable is plugged into the
boiler. Check the cable is plugged into the
Alde control panel.
The boiler will not ignite on gas, but no
error message
The system may not need to use gas heating
if also using electric heating.
The fluids in the boiler may already be at
operating temperature.
The boiler will not heat on 230 V electric
Check the circuit breaker and any 230 V
fuses.
Check that any 230 V isolator switches are
on (they will often have an LED indicator and
230V fuse).
• Check the 230 V supply to the vehicle.
The fluids in the boiler may already be at
operating temperature.
No hot water
Check that Hot Water Ignore is not activated
on the Alde control panel.
Check that Continuous pumping is not
activated on the Alde control panel.
Check for other conflicting settings on the
Alde control panel.
Check the fresh water supply and water
pump.
No central heating
• Bleed the system of air.
• Check the fluid level in the expansion tank.
Check that the circulation pump is
responding.
Check that hot water boost is not activated
on the Alde control panel.
If electric heating is not being used, set it to
“Off” on the Alde control panel.
Use gas and electric heating for best
performance.
Check that vents in the furniture are not
obstructed.
• Check the condition of the heat transfer fluid.
Most vehicles will reach a comfortable
temperature within 40 mins, in non-extreme
conditions.
Circulation pump active even though
system is off
12 V supply to the boiler dropped to 7 V
momentarily. Check 12 V supply for stability.
“Panel failure 1” & “Panel failure 2”
• Moisture is trapped in the control panel.
Remove the Alde control panel from
the vehicle and air in a warm, dry place
overnight.
“Gas failure”
• Out of gas or gas is not igniting.
Check the gas cylinder is full. Try a different
gas cylinder, ensuring it is propane gas.
Check the gas regulator and any isolation
valves are open and not frozen.
“Overheat red fail” or “Overheat blue fail”
• Bleed the system of air.
Check the fluid level in the expansion tank. It
should be 1 cm above Min mark when cool.
Check the correct circulation pump is
installed, selected and responding.
12 V supply to the boiler dropped to 7 V
momentarily. Check 12 V supply for stability.
• Wait 15 mins for the fluid to cool down.

Other manuals for Alde Compact 3020 HE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alde Compact 3020 HE and is the answer not in the manual?

Alde Compact 3020 HE Specifications

General IconGeneral
BrandAlde
ModelCompact 3020 HE
CategoryBoiler
LanguageEnglish

Related product manuals