FITTED EQUIPMENT
143
Operation with batteries
(internal power supply)
Indicator Fault Remedy
(3) and (8)
flashing brightly
Flame not ignited Check gas supply (gas bottle, gas valve)
Press the (8) button after clearing the fault
(3) and (7)
flashing brightly
Burner defective
or cooling unit
defective
Check burner, burner nozzles, if necessary
contact Customer Service and arrange
replacement
Acoustic signal at
15 second intervals
Undervoltage
detection (internal
batteries)
Replace batteries
Automatic
switching from
external to internal
power supply
does not function
(absence of the
onboard 12V power
supply for the
electronics)
Refrigerator does
not function, gas
operation not
possible although
the batteries are
inserted
Switch off the refrigerator and start again
The onboard power supply was interrupted during
the starting of the gas operation
Note: No automatic switching is performed during
the ignition.
Cooker Operation
Cooker 3 Burner + Hotplate
operation
Burner operation
Fig. 1
Important
• Although each burner will support pans from
10 to 22cm, care should be taken not to
overload the appliance as performance may
be reduced.
• The following pan sizes are the maximum
we recommend:- Electric Hotplate:- Ø18cm
Auxiliary Burner:- Ø20cm Semi-Rapid
Burner:- 2x Ø20cm or 1x Ø22cm with
1x Ø18cm
• When using small pans the flames should
not spread beyond the base of the pan as
this will reduce the efficiency of the burner.
• Avoid old or misshapen pans as these may
cause instability.
• The lid must be opened fully prior to using
the hotplate burners.
Using the Hotplate Gas Burners
1. Ensure gas cylinder/supply is connected
and turned on. In the event of a gas smell
turn off at gas cylinder/mains and contact
supplier.
2. Flame supervision: Each burner is
controlled individually and is monitored
by a thermocouple probe. In the event
of the burner flames being accidentally
extinguished, turn off the burner control and
do not attempt to re-ignite the burner for at
least one minute.
DOMETIC REFRIGERATOR/COOKER