Maintenance
Step 3
Drain the heat exchanger.
Note!
Avoid vacuum in the heat e xchanger by ope ning the
vent valves.
Step 4
Remove the pr otection sheets, if any.
Step 5
Dismantle pipes from the pressure plate s o that the pressure
plate are free to move along the carrying bar.
Step 6
Inspect the sliding surfaces of the carrying bar and wipe clean
and grease.
Step 7
Mark the plate a ssembly on the outside by a diagonal li ne.
Step 8
Measure and note the dimension A.
Document ID La nguage Edition
3490010217 EN 2016-06 Instruction Ma nual - Plate Heat Exchan gers 21